====== Câbles/Sections/Ampérages ====== Cette page regroupe les informations de concordance entre section et ampérage pour les différents câbles électroniques / électriques utilisables dans les différents montages ===== Par AWG ===== ^AWG ^Section [mm2] ^Diamètre [mm] ^R [Ωm] @ 20°C ^Imax [A] (1)^ |8AWG |8.37 |3.26 |0.00206 |73 | |10AWG |5.26 |2.59 |0.00328 |55 | |12AWG |3.31 |2.05 |0.00521 |41 | |14AWG |2.08 |1.63 |0.00829 |32 | |16AWG |1.31 |1.29 |0.0132 |22 | |18AWG |0.977 |1.02 |0.0209 |16 | |20AWG |0.518 |0.81 |0.0333 |11 | |22AWG |0.326 |0.64 |0.05295 |7 | |24AWG |0.205 |0.52 |0.0842 |3.5 | |26AWG |0.129 |0.42 |0.134 |2.2 | |28AWG |0.0810 |0.32 |0.213 |1.4 | |30AWG |0.0509 |0.25 |0.339 |0.86 | |32AWG |0.0320 |0.20 |0.538 |0.53 | |34AWG |0.0201 |0.16 |0.856 |0.33 | |36AWG |0.0127 |0.13 |1.361 |0.21 | ===== Câbles par section "classique" ===== Section 0.75mm2 en multi-brins (ex. : câble HiFi): 12A //(source : https://www.sab-cable.eu/cables-confection-technique-de-thermometrie/donnees-techniques/cables/regles-de-securite-pour-lutilisation-des-cables/conditions-limites-dutilisation/tableaux-des-intensites-de-courant-maxi-admissible-e-coefficient-de-correction.html) //